Medtronic Covidien ValleyLab Force FX-C

Refurbished

Refurbished

Covidien Force FX is a high-power digital electrosurgical unit.

Final price will be confirmed in quote

View cart above to complete quote request.

Description

The Force FXc Electrosurgical Generator with instant response technology provides surgeons with improved performance at lower power settings, minimizing the risk of tissue damage and neuromuscular stimulation, and decreasing the need to “turn up the generator.” It adjusts automatically, responding to tissue changes, maintaining power delivery, and minimizing drag for a smoother cut through all tissue types.

Added safety and reliability minimizes electrosurgical risks. Capacitive coupling is reduced by 30 – 50% when using instant response technology. This reduction is achieved by limiting the RMS voltage and the high-frequency harmonics. Lower voltage means less neuromuscular stimulation and more precise delivery of energy to reduce collateral damage.

  • Instant Response technology that ensures the power delivered remains virtually constant, regardless of the tissue type.
  • Three internal microcontrollers that reduce system reaction time and increase the system’s processing speed.
  • Capacitive coupling is reduced by 30-50 percent when using Instant Response TM technology. This reduction is achieved by limiting the RMS voltage and the high-frequency harmonics. Lower voltage means less neuromuscular stimulation and more precise delivery of energy to reduce collateral damage.
  • Spray coagulation voltage of no more than 9000 volts for broad, but superficial coagulation with limited capacitive coupling.
  • Compatible with the exclusive Computer Motion Hermes Voice Command System.

Specifications

  • Height: 4.375 in ( 11.1 cm)
  • Width: 14 in (35.6 cm)
  • Depth: 18 in (45.7 cm)
  • Weight: 18 lbs (<8.2 kg)

Description

The Force FXc Electrosurgical Generator with instant response technology provides surgeons with improved performance at lower power settings, minimizing the risk of tissue damage and neuromuscular stimulation, and decreasing the need to “turn up the generator.” It adjusts automatically, responding to tissue changes, maintaining power delivery, and minimizing drag for a smoother cut through all tissue types.

Added safety and reliability minimizes electrosurgical risks. Capacitive coupling is reduced by 30 – 50% when using instant response technology. This reduction is achieved by limiting the RMS voltage and the high-frequency harmonics. Lower voltage means less neuromuscular stimulation and more precise delivery of energy to reduce collateral damage.

  • Instant Response technology that ensures the power delivered remains virtually constant, regardless of the tissue type.
  • Three internal microcontrollers that reduce system reaction time and increase the system’s processing speed.
  • Capacitive coupling is reduced by 30-50 percent when using Instant Response TM technology. This reduction is achieved by limiting the RMS voltage and the high-frequency harmonics. Lower voltage means less neuromuscular stimulation and more precise delivery of energy to reduce collateral damage.
  • Spray coagulation voltage of no more than 9000 volts for broad, but superficial coagulation with limited capacitive coupling.
  • Compatible with the exclusive Computer Motion Hermes Voice Command System.

Specifications

  • Height: 4.375 in ( 11.1 cm)
  • Width: 14 in (35.6 cm)
  • Depth: 18 in (45.7 cm)
  • Weight: 18 lbs (<8.2 kg)