Medfusion 2010i syringe pump may be utilized whenever meticulous low volume drug on fluid injections using a syringe are required in the hospital. The 2010i may be field customized for specific applications. A bolus may be programmed, then changed or administered at any time prior to or during drug delivery.

Features

  • Programmable for four types of infusion – Body Weight Mode; Mass Mode; Continuous Mode; Volume Over Time Mode
  • Ability to store up to 64 user regimens/protocols

Specifications

  • Flow rate: 0.01-378.0 ml/hr dependent upon syringe size
  • Bolus rate: up to 378.0 ml/hr dependent upon syringe size
  • Total Volume Delivered: 0.0000-9999 mg. ml or units
  • Accuracy: ±3%
  • Infusion Modes: Body Weight, Mass, Continuous and Volume/time
  • Accepts B-D, Monoject and Terumo syringes
  • Accepts: B-D 1 TB, 1, 3, 5, 10, 20, 30, 60 ml Luer lock
  • Monoject 1 TB, 3, 6, 12, 20, 35, 60 ml Luer lock
  • Terumo 1 TB, 3, 5, 10, 20, 30, 60 ml Luer lock
  • B-D (glass) 1, 3, 5, 10 ml
  • Automatically adjusts the output PSI for different syringe sizes
  • Automatically sense syringe size, syringe barrel placement and syringe plunger placement
  • All syringes will fill to their maximum
  • Power: AC-internal battery
  • Recharge Time: No longer than 16 hours with the pump turned off
  • Battery Capacity: at 25C a 16 hour charge will operate the pump for approximately 10 hours at 5.0 ml/hr with a 60 ml syringe
  • At 25 degrees C a 16 hour charge will pump approx. 10 hrs at 5.0 ml/hr with a 60 ml syringe
  • Alarms: Near Empty, Empty, Occlusion, System Malfunction, Low/Depleted Battery, Load Syringe Plunger, Check Clutch, Syringe Pops Out, Invalid Size, Invalid Number, Alarm Audio Volume, soft/loud, Alarm Temporary Delay
  • Status Alerts: Stop/Program, Deliver, Battery In Use, Battery Charging, Priming, Back Light, Standby Mode, Bolus Delivery, End of Bolus
  • Water resistant case
  • Suitable for arterial infusions
  • Weight: 2.5 lbs.
  • 4.5″ (w) × 3″ (h) × 7.5″ (w)

Description

Medfusion 2010i syringe pump may be utilized whenever meticulous low volume drug on fluid injections using a syringe are required in the hospital. The 2010i may be field customized for specific applications. A bolus may be programmed, then changed or administered at any time prior to or during drug delivery.

Features

  • Programmable for four types of infusion – Body Weight Mode; Mass Mode; Continuous Mode; Volume Over Time Mode
  • Ability to store up to 64 user regimens/protocols

Specifications

  • Flow rate: 0.01-378.0 ml/hr dependent upon syringe size
  • Bolus rate: up to 378.0 ml/hr dependent upon syringe size
  • Total Volume Delivered: 0.0000-9999 mg. ml or units
  • Accuracy: ±3%
  • Infusion Modes: Body Weight, Mass, Continuous and Volume/time
  • Accepts B-D, Monoject and Terumo syringes
  • Accepts: B-D 1 TB, 1, 3, 5, 10, 20, 30, 60 ml Luer lock
  • Monoject 1 TB, 3, 6, 12, 20, 35, 60 ml Luer lock
  • Terumo 1 TB, 3, 5, 10, 20, 30, 60 ml Luer lock
  • B-D (glass) 1, 3, 5, 10 ml
  • Automatically adjusts the output PSI for different syringe sizes
  • Automatically sense syringe size, syringe barrel placement and syringe plunger placement
  • All syringes will fill to their maximum
  • Power: AC-internal battery
  • Recharge Time: No longer than 16 hours with the pump turned off
  • Battery Capacity: at 25C a 16 hour charge will operate the pump for approximately 10 hours at 5.0 ml/hr with a 60 ml syringe
  • At 25 degrees C a 16 hour charge will pump approx. 10 hrs at 5.0 ml/hr with a 60 ml syringe
  • Alarms: Near Empty, Empty, Occlusion, System Malfunction, Low/Depleted Battery, Load Syringe Plunger, Check Clutch, Syringe Pops Out, Invalid Size, Invalid Number, Alarm Audio Volume, soft/loud, Alarm Temporary Delay
  • Status Alerts: Stop/Program, Deliver, Battery In Use, Battery Charging, Priming, Back Light, Standby Mode, Bolus Delivery, End of Bolus
  • Water resistant case
  • Suitable for arterial infusions
  • Weight: 2.5 lbs.
  • 4.5″ (w) × 3″ (h) × 7.5″ (w)