Drager Apollo Anesthesia Machine

Refurbished

Refurbished

Drager Apollo Anesthesia Machine includes a built-in gas module, built-in gas (anesthetic agents, CO2, O2) display, container of Sodasorb, O2 sensor, two flow sensors, two new batteries, power cord, and software version 04.53.05.

Final price will be confirmed in quote

View cart above to complete quote request.

Description

  • 9E-Vent plus servo controlled high-speed piston ventilator works with great precision to supply a
    maximum peak flow far in excess of any bellows ventilator, resulting in the kind of performance
    previously only seen in the ICU
  • Requires no drive gas
  • Designed to support the user by providing optimal low and minimal flow settings
  • Simple straightforward startup makes it easier for the staff and provides complete information
    on device status
  • Enhanced troubleshooting with clear text directions
  • Integrated breathing system eliminates external hoses and clutter, reducing the risk of
    misconnection and disconnection
  • Fully automatic self-test lasts approximately three minutes, reflects the results to the user, and
    makes results available to the user at any time
  • Inspiratory and expiratory concentration of O2, N2O, CO2 as well as anesthetic agents
    (Halothane, Enflurane, Isoflurane, Sevoflurane, Desflurane); Minute volume (MV) and Tidal
    volume (VT); Breathing frequency; Peak pressure, plateau pressure, mean pressure, PEEP;
    Patient compliance CPAT

Specifications

  • Weight: 365 lb (165 kg) without vaporizers and gas cylinders.
  • Dimensions: 59″ (H) x 33.5″ (W) x 31.5″ (D) (150 cm x 85 cm x 80 cm).
  • Power: 200 W, typically.
  • Operating Voltage: 100 to 127 VAC (-15% + 10%), 45 – 65 Hz.
  • Integrated Power Backup: At least 30 min, typically 90 min; Depending on ventilation parameters.
  • Ventilator E-Vent plus: Electrically driven and electronically controlled, fresh gas decoupled.
  • Ventilation Modes:
    o Standard: Manual, spontaneous, Volume Mode, Pressure Mode.
    o Optional/Synchronization: Pressure Support (PS).
  • Pressure Limitation PMAX (in Volume Mode): (PEEP + 10) up to 70 cmH2O.
  • Pressure Limitation PINSP (in Pressure Mode): (PEEP + 5) up to 70 cmH2O.
  • Trigger: 0.3 – 15 L/min.
  • Tidal Volume VT (compliance compensated) (in Volume Mode):
    o Standard: 20 – 1400 mL.
    o With Advanced Ventilation option: 5 – 1400 mL.
  • Breathing Frequency: 3 – 100 bpm.
  • Inspiration Time (TINSP): 0.2 – 6.7 s.
  • Inspiration/Expiration Time Ratio (I:E): 5:1 max.
  • Plateau Time (TIP:TINSP): 0 – 60%.
  • Inspiratory Flow (in Pressure Mode): 150 L/min max.
  • PEEP:
    o In Volume Mode: 0 – 20 cmH2O (max. PMAX – 10 cmH2O).
    o In Pressure Mode: 0 – 20 cmH2O (max. PINSP – 5 cmH2O).
  • Fresh-Gas Flow: 0 – 10 L/min for each gas (oxygen, air, nitrous oxide).
  • TSLOPE (in Pressure Mode and Pressure Support): 0 – 2 s.
  • Total System Leakage: < 150 mL/min at 30 cmH2O (automatic leak test).
  • O2 Flow Control: Sensitive ORC Function: At least 21 Vol.-% with N2O as carrier gas.
  • O2 Flush: > 35 L/min
  • Serial Interface: 2 x RS 232
  • Protocol: Medibus, Medibus X
  • Absorber Volume (reusable canister): 1.5 L

Description

  • 9E-Vent plus servo controlled high-speed piston ventilator works with great precision to supply a
    maximum peak flow far in excess of any bellows ventilator, resulting in the kind of performance
    previously only seen in the ICU
  • Requires no drive gas
  • Designed to support the user by providing optimal low and minimal flow settings
  • Simple straightforward startup makes it easier for the staff and provides complete information
    on device status
  • Enhanced troubleshooting with clear text directions
  • Integrated breathing system eliminates external hoses and clutter, reducing the risk of
    misconnection and disconnection
  • Fully automatic self-test lasts approximately three minutes, reflects the results to the user, and
    makes results available to the user at any time
  • Inspiratory and expiratory concentration of O2, N2O, CO2 as well as anesthetic agents
    (Halothane, Enflurane, Isoflurane, Sevoflurane, Desflurane); Minute volume (MV) and Tidal
    volume (VT); Breathing frequency; Peak pressure, plateau pressure, mean pressure, PEEP;
    Patient compliance CPAT

Specifications

  • Weight: 365 lb (165 kg) without vaporizers and gas cylinders.
  • Dimensions: 59″ (H) x 33.5″ (W) x 31.5″ (D) (150 cm x 85 cm x 80 cm).
  • Power: 200 W, typically.
  • Operating Voltage: 100 to 127 VAC (-15% + 10%), 45 – 65 Hz.
  • Integrated Power Backup: At least 30 min, typically 90 min; Depending on ventilation parameters.
  • Ventilator E-Vent plus: Electrically driven and electronically controlled, fresh gas decoupled.
  • Ventilation Modes:
    o Standard: Manual, spontaneous, Volume Mode, Pressure Mode.
    o Optional/Synchronization: Pressure Support (PS).
  • Pressure Limitation PMAX (in Volume Mode): (PEEP + 10) up to 70 cmH2O.
  • Pressure Limitation PINSP (in Pressure Mode): (PEEP + 5) up to 70 cmH2O.
  • Trigger: 0.3 – 15 L/min.
  • Tidal Volume VT (compliance compensated) (in Volume Mode):
    o Standard: 20 – 1400 mL.
    o With Advanced Ventilation option: 5 – 1400 mL.
  • Breathing Frequency: 3 – 100 bpm.
  • Inspiration Time (TINSP): 0.2 – 6.7 s.
  • Inspiration/Expiration Time Ratio (I:E): 5:1 max.
  • Plateau Time (TIP:TINSP): 0 – 60%.
  • Inspiratory Flow (in Pressure Mode): 150 L/min max.
  • PEEP:
    o In Volume Mode: 0 – 20 cmH2O (max. PMAX – 10 cmH2O).
    o In Pressure Mode: 0 – 20 cmH2O (max. PINSP – 5 cmH2O).
  • Fresh-Gas Flow: 0 – 10 L/min for each gas (oxygen, air, nitrous oxide).
  • TSLOPE (in Pressure Mode and Pressure Support): 0 – 2 s.
  • Total System Leakage: < 150 mL/min at 30 cmH2O (automatic leak test).
  • O2 Flow Control: Sensitive ORC Function: At least 21 Vol.-% with N2O as carrier gas.
  • O2 Flush: > 35 L/min
  • Serial Interface: 2 x RS 232
  • Protocol: Medibus, Medibus X
  • Absorber Volume (reusable canister): 1.5 L